【Scope of application】
The air gauge adopts the principle of pitot tube type, which automatically detects the air pressure at multiple points and multiple times, and produces the average air volume (m3/h) with the characteristics of correctness, speed and simplicity, which is widely used in HVAC, purification technology and other industries for direct measurement of air volume and duct air volume, so as to implement comprehensive management of air volume of centralized air conditioning and automatic control of temperature, humidity, cleanliness and other parameters. In order to facilitate the customer’s on-site inspection work, we are specially equipped with a mobile bracket, which can be raised up to 2.2m (including 0.9m of the anemometer body), and the overall can be raised to 3.1m. The FL type air gauge can measure the air supply and return air outlets, bringing convenience to testing. Each FL type air gauge is factory with multi-point air volume correction through a strict 0.5 level standard wind tunnel calibration device, providing a reliable guarantee for users to directly measure air volume
【Relevant Standards】
【Scope of application】:
The air gauge adopts the principle of pitot tube type, which automatically detects the air pressure at multiple points and multiple times, and produces the average air volume (m3/h) with the characteristics of correctness, speed and simplicity, which is widely used in HVAC, purification technology and other industries for direct measurement of air volume and duct air volume, so as to implement comprehensive management of air volume of centralized air conditioning and automatic control of temperature, humidity, cleanliness and other parameters. In order to facilitate the customer’s on-site inspection work, we are specially equipped with a mobile bracket, which can be raised up to 2.2m (including 0.9m of the anemometer body), and the overall can be raised to 3.1m. The FL type air gauge can measure the air supply and return air outlets, bringing convenience to testing. Each FL type air gauge is factory with multi-point air volume correction through a strict 0.5 level standard wind tunnel calibration device, providing a reliable guarantee for users to directly measure air volume
【Technical Parameters】:
1. Model F-1 type anemometer
2. Basic functions
LCD display Equipped with a printing interface, the built-in battery can last up to 30 hours and does not lose data after power failure (within 4 hours).
3. Measurement range 100~3500m3/h
4. Relative error: Full scale± 5% F.S
5. Self-resistance ≤5Pa
6. Automatically store the air volume value of 1000 air outlets
【Usage Environment】:
1. Temperature: 5~35°C
2. Relative humidity: 15%~70%RH
3. It is strictly forbidden to measure corrosive gases