【Scope of application】
Test the thermal insulation performance of the insulation suit placed horizontally when exposed to radiant heat sources.
【Relevant Standards】
GB 38453-2019 and other standards.
【Scope of application】:
Test the thermal insulation performance of the insulation suit placed horizontally when exposed to radiant heat sources.
[Meet the standard]:
GB 38453-2019 and other standards.
[Instrument features]:
1. Color touch screen display and control, Chinese and English interface, menu operation mode.
2. The core control components use ST’s 32-bit microcontroller to form a multi-function motherboard.
3. The radiation source adopts 6 silicon-carbon heating tubes, and the maximum heating capacity can reach 1200°C.
4. Equipped with a calorie calibration calibrator, which can quickly complete the calibration to ensure the accuracy of the data.
5. The whole machine is composed of radiation device, specimen clamping device and control system.
6. Intelligent water circulation control system.
7. Metal protective shield, equipped with waterway cooling device.
8. Computer software connection continuously records and displays the temperature curve in real time.
【Technical Parameters】:
1. The radiant heat source is composed of 6 silicon-carbon heating tubes.
2. Heat source heat flux range: ≤30kW/m²;
3. Specimen size: 230mm×80mm;
4. Copper calorimeter measurement range: 0°C~300°C, resolution 0.1°C, accuracy 0.2°C;
5. Computer display and processing, with real-time curve, result printing;
6. Timing range and accuracy: 0~99999.9s, accuracy 0.1s;
7. Computer online, automatic data collection, collection frequency ≥ 10 Hz, including heat flow data software;
8. Power supply: AC220/50Hz Power: ≤9KW;
9. Customize ventilation equipment based on the actual situation of the place of use;
10. The size of the whole machine is L×W×H: 1500mm× 650mm× 1200mm